PVC conduit question - ElectriciansForums.net Est.2006 | Free ...
Dec 4, 2024 · Hi all, I'm not so familiar with pvc conduit having used it very little in the past. However, I have a small workshop/man-cave to wire, it is attached to a small domestic dwelling. I need to wire this part using 20mm conduit. I have a few questions: 1: Am I right in thinking I can wire multiple circuits together in the same conduit?
VFD for old Myford ML8 wood lathe (0.5HP, single phase)
Aug 14, 2015 · Using VFD's on old single phase motors is likely to end in tears for several reasons. If I was doing this as a project I'd look at replacing the single phase motor with a 3-phase one then I'd use a VFD that had a single phase 230v input and a 400v 3-phase output, it would be a much better end result.
Late Part P Submission? - ElectriciansForums.net Est.2006
Jun 9, 2015 · Hi, Ive gotten behind on my paperwork over the last few months and have lapsed on my Part P notifications for jobs in that time. I am an NICEIC approved contractor/domestic installer. NICEIC class a submission older than 25 days past the works completion date as a 'late submission'...
Is a taped joint really that bad? - Electricians Forums
Oct 15, 2019 · Don't worry, in 20 or 30 years people will be laughing at the way dangerous 230volt cables were run all over houses and hidden in walls and floors. Reply Reactions: DPG , Mark42 , Lucien Nunes and 1 other person
problem with Dimplex Duo300n heaters - Electricians Forums
Dec 12, 2021 · So don't worry about that, just leave the controller 'off' for the time being. The curious thing is though, that the instructions for the controller do say that the controller should be set to 'comfort' (the sort of sun symbol) for the heaters background mode to work. see the trouble shooting part of the guide here:
Anybody have experience with DiLog DL9118 MFT?
Oct 16, 2017 · Generally a good test kit, don't think you can go wrong with the price. Big plus in my opinion is you get a Celebration cert and the option of paying £60 for the first 3 years to get dialog to calabrate and provide firmware updates.
Mains electric shock from plastic light switch - no fault found by ...
Jun 6, 2022 · Occasionally, perhaps once or twice a year, the lights controlled by the problem switch would strobe brightly when off, disco style. This would last for maybe a couple of hours, during which time he claimed that touching the switch would give little shocks, which seemed to be from the switch rather than the (metal) switch plate.
Axiom SPD consumer unit - ElectriciansForums.net Est.2006
Apr 18, 2020 · Use this Axiom consumer unit to power all the electrical circuits in your home. The distribution board provides full circuit protection and is easy for an electrician to install. You don't need to worry about this product posing a safety hazard, …
Clipped Direct - ElectriciansForums.net Est.2006 | Free Electrical ...
May 3, 2011 · That's no reason to condem it. I don't think anyone would claim it's a good installation (certainly not from a mechanical protection perspective). But technically nothing wrong with it. Perhaps he thinks that the "voltage is leaking" PMSL, I bet if you ask him he thinks voltage flows down cables as well!!
High EFLI on TN-S, DNO won't fix | on ElectriciansForums
Mar 20, 2017 · UKPN came out last week and did some tests. They confirmed the EFLI reading as fluctuating between 6 and 11.5. The main earth in my house is clamped to an incoming pipe and the UKPN guy confirmed my setup was TN-S (can post a couple of photos if helpful).